229 SD700 Series Servo Technical Manual 0MHz ~ 1MHz filtering. 35: Grating ruler pulse output, grating ruler power supply is invalid, 0MHz ~ 1MHz filtering. 48: Encoder pulse frequency division output, grating ruler power supply is effective, 0MHz ~ 500kHz filtering. 49: Grating ruler pulse output, grating ruler power supply is effective, 0MHz ~ 500kHz filtering. 50: Encoder pulse frequency division output, grating ruler power supply invalid, 0MHz ~ 500kHz filtering 51: Grating ruler pulse output, grating ruler power supply invalid, 0MHz ~ 500kHz filtering. 51:Grating ruler pulse output, grating ruler power supply is invalid, 0MHz ~ 500MHz filtering.
Pn045 Under-voltage function selection 0~2 1 - 0x0045 After restart 0 - No Detection of main circuit drop warning. 1 - Detect main circuit drop warning. 2 - Detect main circuit drop warning and perform torque limit. The relevant torque limit is matched with Pn046/Pn047. For details, refer to “Torque limit when main circuit voltage drops”. Pn046 Torque limit when main circuit voltage drops 0~100 50 % 0x0046 Immediately According to the under voltage warning, it will impose the torque limit inside the servo unit. For details, see the “Torque limit when under voltage” instruction.
Pn047 Torque limit release time when main circuit voltage drops 0~1000 100 ms 0x0047 Immediately After the under-voltage warning signal releases, the torque limit value is controlled within the servo unit according to the setting time. For details, see “Torque limit when the main circuit under-voltage”. Pn050 Torque limit setting 0~4 1 - 0x0050 Immediately 0- Analog torque (torque mode is invalid). 1- Maximum torque limit 1. 2- Maximum torque limit 1 when forward running; maximum torque limit 2 when reverse running. 3- Maximum torque limit 1 when the “Torque Limit Switching” switch is OFF while Maximum torque limit 2 when it’s ON. 4- Limit by the torque command(valid when in torque mode).
Pn051 Maximum torque limit 1 0~500 500 % 0x0051 Immediately Pn052 Maximum torque limit 2 0~500 500 % 0x0052 Immediately Pn053 Emergency stop torque 0~800 800 % 0x0053 Immediately The torque when set the motor to deceleration stop. Pn061 Panel parameter display selection 0x00~ 0x01 1 - 0x0061 After restart 0 - Only display setting parameters. 1 - Show all parameters. Pn070 Encoder frequency division pulses 16~ 4194304 2048 - 0x0070 After restart The number of pulses per cycle from the encoder is divided by frequency in accordance with the set value of this parameter. Please set it according to the system specifications of the machine and host device. Note:
The set value is the number of A/B quadrature output pulses in one turn. The setting of the number of encoder division pulses will be limited due to the resolution of the encoder. For details, see the “Division pulses output setting” instruction. Pn072 Frequency division output inversion 0~1 0 - 0x0072 After restart