VEICHI — SD700 User Manual 20230516

10.2 Pn1 Group Gain Parameters 231 SD700 Series Servo Technical Manual be valid for tamogawa encoder above 130 (including) flange only when bit4 of Pn08c must equal to 1, and Pn08b is written into encoder EEPROM, otherwise it will not be executed (Pn08b = 0, turn off over temperature alarm function). Encoder alarm detection selection 0x00~ 0x11 0x00 - 0x008C After restart Pn08C Only when bit4 of Pn08c must equal to 1, and Pn08b is written into encoder EEPROM, or it will not be executed.

Function code Parameter Range Default Unit Communication When enabled address Pn100 Rotary inertia ratio 0~ 100 % 0x0100 Immediately 20000 Rotary inertia ratio = converted load inertia of motor shaft / rotor rotary inertia of servo motor *100%. Pn101 First speed gain 1~2000 40.0 Hz 0x0101 Immediately It becomes a delay element of the outer position loop when the response of the speed loop is low, so overshoot or vibration of the speed command occurs. In the range where the mechanical system does not vibrate, the larger the value is set, the more stable the servo system becomes and the better the responsiveness will be.

Pn102 First speed integration 0.15~ 20.00 ms 0x0102 Immediately time constant 512 In order to respond to small input, the speed loop contains integral elements. Since this integral element is a delay factor for the servo system, when the time parameter is set too large, overshoot may occur, or the positioning time may be extended meanwhile resulting in poor responsiveness. Pn103 First position gain 1~2000 40.0 1/s 0x0103 Immediately The position loop response is determined by the position loop gain. The higher the setting of the position loop gain is, the higher the responsiveness and the shorter the positioning time will be.

The position loop gain cannot be increased beyond the rigidity of the mechanical system. If you want to increase the position loop gain to a larger value, the rigidity of the machine must be increased. Pn104 First torque command 0~ 1.00 ms 0x0104 Immediately filter 655.35 Adjusting the parameters of the torque command filter may eliminate the machine vibration caused by the servo drive. The smaller the value is, the better the responsiveness can be. However, the conditions are restricted by the machine conditions.

Pn105 Second speed gain 1~2000 40.0 Hz 0x0105 Immediately See Pn101 Pn106 Second speed 0.15~ 512 20.00 ms 0x0106 Immediately integration time constant See Pn102 Pn107 Second position gain 1~2000 40.0 1/s 0x0107 Immediately See Pn103 Pn108 Second torque 0~ 1.00 ms 0x0108 Immediately command filter 655.35 See Pn104