232 SD700 Series Servo Technical Manual Pn110 Gain switching mode selection 0x00~ 0x01 0 - 0x0110 Immediately The gain switching function includes two methods, “Manual gain switching” using an external input signal and “Automatic gain switching” automatically switch. By using the gain switching function, gain can be increased and positioning time can be shortened during the positioning time. When the motor is stopped, reduce gain and suppress vibration. 0- Manual gain switch by using the external input signal (G-SEL). 1- When the automatic switching condition is met (Pn111), it automatically switches from the first gain to the second gain; otherwise, it switches back to the first gain.
Pn111 Gain automatic switching condition of position control 0x00~ 0x05 0 - 0x0111 Immediately Set the conditions for automatic gain switching: 0-Positioning completion signal ON. 1-Positioning completion signal OFF. 2-Positioning proximity signal ON. 3-Positioning proximity signal OFF. 4-Position command is 0 after filtering and pulse input is OFF. 5-Position command pulse input is ON. If the conditions are met, then switch to the second gain, otherwise switch to the first gain.
Pn112 Gain switching transition time 1 0~ 65535 0 ms 0x0112 Immediately Starting from the time when the switching condition has been established, after the waiting time, change the gain of the 1st position loop to the gain of the 2nd position loop in a straight line within the switching transition time. Pn113 Gain switching transition time 2 0~ 65535 0 ms 0x0113 Immediately Starting from the time when the switching condition has been established, after the waiting time, change the gain of the 2nd position loop to the gain of the 1st position loop in a straight line within the switching transition time.
Pn114 Gain switching waiting time 1 0~ 65535 0 ms 0x0114 Immediately It refers to the time when the switching conditions the 1st gain to the 2nd gain is established and the switching really starts. Pn115 Gain switching waiting time 2 0~ 65535 0 ms 0x0115 Immediately It refers to the time when the switching condition of the 2nd gain to the 1st gain is established and the switching really starts. Pn121 Speed feedforward gain 0~100 0 % 0x0121 Immediately Speed feedforward is a function to shorten the positioning time. This function is effective when position control. Note: position overshoot will occur when the feedforward command is too large.
Please set it appropriately while observing the response. Pn120 Position integral time constant 0.0~ 5000.0 0.0 ms 0x0120 Immediately Pn122 Speed feedforward filter time 0~64 0.00 ms 0x0122 Immediately Speed feedforward low-pass filter time constant can slow position overshoot and torque jump caused by feedforward. Pn123 Use V-REF as speed feedforward selection 0x00~ 0x01 0 - 0x0123 After restart Speed feedforward is a function to shorten the positioning time. It is possible to select speed feed forward via external analog V-REF. 0-None.