233 SD700 Series Servo Technical Manual 1- Use V-REF as speed feed forward input. Pn124 Speed/position control selection (T- REF assignment) 0~1 0 - 0x0124 After restart Torque feedforward is a function to shorten the positioning time. Torque feedforward can be selected by external analog T-REF. 0-None. 1- Use T-REF as a torque feed forward input. Pn125 Time constant of speed feedback filtering 0.0~ 655.35 0.0 ms 0x0124 After restart Pn126 Velocity feedback moving average filter time constant 0x0000~ 0x0014 0 125us 0x0124 After restart Pn130 Speed loop control method (PI/IP) 0~1 0 - 0x0130 After restart 0-PI control. 1-IP control.
Pn131 Speed loop P-PI switching condition selection 0x00 0x04 0 - 0x0131 Immediately This is a function that automatically switches P control and PI control. Through setting the switching condition by this parameter and meeting the corresponding switching condition can suppress overshoot during acceleration and deceleration and shorten the settling time. 0- Conditioned by internal torque command. 1- Conditioned by speed instruction. 2- Conditioned by acceleration. 3- Conditioned by position deviation pulse. 4- No mode switch function.
Pn132 Speed loop P-PI switching condition (torque command) 0~800 200 % 0x0132 Immediately When the torque command exceeds the torque set by this parameter, the speed loop will be switched to P control, otherwise PI control. Pn133 Speed loop P-PI switching condition (speed command) 0~ 10000 0 rpm 0x0133 Immediately When the speed command exceeds the speed set by this parameter, the speed loop will be switched to P control, otherwise PI control. Pn134 Speed loop P-PI switching conditions (acceleration) 0~ 30000 0 rpm/s 0x0134 Immediately When the speed command exceeds the acceleration set by this parameter, the speed loop will be switched to P control, otherwise PI control.
Pn135 Speed loop P-PI switching conditions (position deviation) 0~ 10000 0 command unit 0x0135 Immediately When the position deviation exceeds the value set by this parameter, the speed loop will be switched to P control, otherwise PI control. Pn136 The speed loop P/PI switching condition (line) (speed) 0~ 10000 0 mm/s 0x0136 Immediately Pn137 Speed loop P/PI switching condition 0~ 30000 0 mm/s² 0x0137 Immediately