VEICHI — SD700 User Manual 20230516

235 SD700 Series Servo Technical Manual The smaller the notch filter depth value is, the deeper the depression and the higher the vibration suppression effect will be. But setting it too small will increase the vibration. Pn156 Notch filter 2 frequency 50~ 5000 5000 Hz 0x0156 Immediately Set the frequency of the second notch filter that suppresses resonance. When this parameter is set to 5000, the function of the notch filter is invalid. Note: Do not set the notch filter frequency close to the response frequency of the speed loop. At least this frequency should be set to more than 4 times of the speed loop gain, otherwise it may affect the overall performance of the system.

Pn157 Notch filter 2Q value 0.5~10 0.70 - 0x0157 Immediately The Q value of the notch filter refers to the setting value of the filter frequency width related to the notch filter frequency. The width of the recess varies with the Q value of the notch filter, and the larger the Q value of the notch filter is set,the more sunk and the narrower the width of the filter frequency will be. Pn158 Notch filter 2 depth 0~1 0.000 - 0x0158 Immediately The notch filter depth refers to the setting of the filter frequency depth related to the notch filter frequency. The depth of the recess varies with the depth of the notch filter.

The smaller the notch filter depth value is, the deeper the depression and the higher the vibration suppression effect will be. But setting it too small will increase the vibration. Pn160 Disturbance compensation function selection 0x00~ 0x01 0 - 0x0160 Immediately 0- Not use. 1- Use. Pn161 Disturbance observer cutoff frequency 1~1000 150.0 Hz 0x0161 Immediately Set the disturbance compensation gain. Increasing it can improve the effect of suppressing the disturbance, but excessive noise will occur.

Pn163 Disturbance compensation coefficient 0~100 0 % 0x0163 Immediately Set the disturbance compensation coefficient, that is, the received position command or speed command plus the disturbance compensation value of torque command. Pn165 Disturbance observer inertia correction coefficient 1~1000 100 % 0x0165 Immediately The disturbance observer inertia is set by this parameter to adjust the identification error caused by inaccurate inertia setting. Note: When the inertia ratio is set correctly, the value is set to 100. Pn166 Speed observer switch 0~1 0 0x0166 After restart Set speed observation function switch: 0- Invalid. 1- Valid.

Pn167 Speed observer cutoff frequency 1~500 80 Hz 0x0167 Immediately This parameter sets the speed observer bandwidth. Increasing the set value will increase the response speed of the speed feedback value to track the real speed. If the speed is too large, vibration and noise may occur. Pn170 Friction torque compensation cutoff speed 0~1000 20 rpm 0x0170 Immediately Friction compensation function is a function that compensates for viscous friction and fixed load changes. It is adjusted according to the friction compensation coefficient. Generally, please set the friction compensation coefficient to 95% or less. If the effect is not obvious enough, please increase the