10.3 Pn2 Position Related Parameters 237 SD700 Series Servo Technical Manual Function Parameter Unit Communication When enabled Range Default code address Pulse input filter selection 0~2 0 - 0x0200 After restart Use this parameter to select the position command filter to better suppress the interference in the command pulse. 0-Line drive filter ~1MHz. 1-Collector open-circuit filter. 2-Line drive filter 14MHz~4MHz. 3-Collector open-circuit filter 1MHz. 5-Collector open-circuit filter 0kHz ~ 500kHz. 10- Collector open-circuit filter 0kHz ~ 400kHz. 20- Collector open-circuit filter 0kHz ~ 200kHz. 50- Collector open-circuit filter 0kHz ~ 100kHz. 120- Collector open-circuit filter 0kHz ~ 50kHz.

200- Collector open-circuit filter 0kHz ~ 30kHz. 255- Collector open-circuit 0khz ~ 20kHz. Note: Please set a reasonable filter according to the pulse frequency, otherwise it may cause poor pulse immunity or pulse loss.FPGA versions before 3728 do not support multi-level filtering. Pn200 Pulse input form 0~6 0 - 0x0201 After restart Pn201 0-Pulse + direction positive logic. 1-CW+CCW positive logic. 4- 4 times of quadrature encoding. 5-Pulse + direction negative logic. 6-CW+CCW negative Logic. Pulse input direction negation 0~1 0 - 0x0202 After restart Pn202 Select the negation of pulse input direction: 0-Positive . 1-Negative .

Command pulse input magnification 1~100 1 x1 0x0203 Immediately Set the command pulse input magnification value to be used in conjunction with ON/OFF of the command pulse magnification switching signal for switching the position command pulse input magnification to the parameter setting multiple. Note: If the input pulse frequency is too low and this value set too large, the speed may not be steady. Pn203 Electronic gear ratio numerator 0~ 1073741824 64 - 0x0204 0x0205 Immediately Electronic gear ratio denominator 1~ 1073741824 1 - 0x0206 0x0207 Immediately Position mode full closed loop invalid:

The electronic gear ratio is a function for setting the workpiece movement amount of 1 pulse unit of the upper device input command. Take the screw drive as an example, it has a screw pitch of 10mm, When the host system requires that reduction ratio of the motor shaft and the load side machine is N1/N2 (the motor shaft rotates N2 circles when the load shaft rotates N1 circles ), the set value of the electronic gear ratio is obtained by the following formula: Electronic Gear Ratio numerator /Electronic Gear Ratio denominator = Encoder Resolution / Pulse Number of Upper System 1r * Reduction Ratio N1/N2. Pn204 Pn206