VEICHI — SD700 User Manual 20230516

239 SD700 Series Servo Technical Manual This parameter is set to choose if the low-frequency vibration suppression is automatically set in the intelligent settings, bandwidth settings and other auxiliary functions: 0 - Vibration suppression function won’t be automatically adjusted via auxiliary functions. 1 - Vibration suppression function will be automatically adjusted via auxiliary functions. Pn232 Low-frequency vibration detection sensitivity 0.1~300 40.0 % 0x0232 Immediately This parameter is used to set the sensitivity of low-frequency vibration detection when the positioning is completed.

The smaller the sensitivity is set, the easier it is to automatically detect the low frequency vibration frequency point. Pn235 Low-frequency vibration suppression 1 frequency 1~200 200.0 Hz 0x0235 Immediately This parameter is used to set the frequency of low frequency vibration suppression 1. Pn236 Low Frequency Vibration suppression 1 correction 10~1000 100 % 0x0236 Immediately This parameter is used to set the correction coefficient of low-frequency vibration suppression 1. The larger the value is set, the more obvious the suppression effect of low-frequency is, and setting it too small may cause long positioning time.

Pn237 Low-frequency vibration suppression 2 frequency 1~200 200.0 Hz 0x0237 Immediately This parameter is used to set the frequency of low-frequency vibration suppression 2. Pn238 Low-frequency Vibration Suppression 2 Correction 10~1000 100 % 0x0238 Immediately This parameter is used to set the correction coefficient of low-frequency vibration suppression 2. The larger the value is set, the more obvious the suppression effect of low-frequency is, and settting it too small may cause long positioning time. Pn240 Model tracking control selection 0x00~0x01 0 - 0x0240 Immediately 0- Not use model tracking control. 1- Use model tracking control.

Pn241 Model tracking control gain 1~2000 50.0 1/s 0x0241 Immediately The size of the model tracking control gain determines the response speed of the servo system. If the model tracking control gain is increased, the responsiveness becomes faster and the positioning time becomes shorter. When the model tracking control is effective, the position response and deviation of the servo system are determined by this parameter, rather than position gain. Pn242 Model tracking control attenuation coefficient 50~200 100.0 % 0x0242 Immediately The tracking attenuation coefficient of the model decreases, and the position tuning section is easy to cause excessive overshoot.

If the setting is too small, the position oscillates easily. When the setting increases, the position overshoot decreases, but when the position is too large, the position easily rebounds, causing the positioning time to change long. It is recommended to keep this value, 100%, unchanged during normal use.