240 SD700 Series Servo Technical Manual Pn243 Model tracking control speed feedforward gain 0~1000 100.0 % 0x0243 Immediately The feed forward gain of the model tracking speed is reduced, and the responsiveness is slower, but position overshoot doesn’t easily occur. If the feedforward gain is too small, the position deviation will end in a long time. Pn244 Model tracking control forward torque feedforward gain 0~1000 100.0 % 0x0244 Immediately It’s a forward position command and could be used when adjusting the forward response separately. When it is increased, the torque feed forward rises faster and the positioning time can be shortened appropriately.

Pn245 Model tracking control reverse torque feedforward gain 0~1000 100.0 % 0x0245 Immediately It’s a reverse position command and could be used when adjusting the forward response separately When it is increased, the torque feed forward rises faster and the positioning time can be shortened appropriately. Pn246 Second model tracking control attenuation coefficient 1~2000 50.0 1/s 0x0246 Immediately Use 2nd gain when model tracking is valid. Pn247 Second model tracking control attenuation coefficient 50~200 100.0 % 0x0247 Immediately Use 2nd gain when model tracking is valid.

Pn249 Speed feedforward/torque feedforward selection 0x00~0x01 0 - 0x0249 Immediately 0-Do not use model tracking control, external speed and torque feed forward at the same time. 1-Use model tracking control, external speed and torque feed forward at the same time. When using the model tracking control, the optimal feedforward will be set and it is not recommended to use the “speed feed forward (V-REF) input” and “torque feed forward (T-REF) input” from the upper unit at the same time. However, it can be used at the same time as needed. In this case, if the input feed forward is incorrect, it may cause overshoot and system instability.

Pn250 Application method of external encoder in full closed loop control 0~3 0 - 0x0250 After restart 0 - Full closed loop function is not used . 1 - Use in standard direction. 2 - Use in reverse direction . When setting the forward rotation of the motor, if the moving direction of the grating ruler is set incorrectly, it may cause an alarm of speeding or excessive deviation between the motor and load. Before operation, manually move the load and change this parameter to make the change direction of the monitoring parameter Un007 (feedback pulse counter) and Un012 (feedback pulse counter of external encoder) consistent before operation.