241 SD700 Series Servo Technical Manual Pn252 Deviation coefficient between motor loads of fully closed-loop rotating for 1 turn 0~100 20 % 0x0252 Immediately If this parameter is set to 0%, the deviation will be 1000 after one cycle of operation, and the deviation will be accumulated on the basis of 1000 at the beginning of the second cycle of operation. If it is set to 20%, the deviation will be accumulated on the basis of 200(1000) at the beginning of the second cycle of operation. If the value is set too large, Er.d10 may not be detected normally. It needs to be set according to the load and the allowable installation error between motors.
Pn253 Resolution of external grating ruler 4~ 1048576 32768 Pulse /r 0x0253 0x0254 After restart Set the resolution of the external grating ruler after the motor runs for 1 turn (after 4 times the frequency). Pn257 Setting of excessive deviation between motor and load 0~ 1073741824 1000 Command unit 0x0257 0x0258 Immediately Set the alarm threshold value of excessive deviation between motor and load, which is too small, which may lead to false detection of Er.d10.
Pn260 Position proximity signal width 1~ 1073741824 1073741 824 Command unit 0x0260 0x0261 Immediately In the position control, the host device can receive the positioning proximity signal before confirming the positioning completion signal, so as to prepare for the sequence of actions after the positioning is completed and shorten the time required for the positioning to complete the operation The signal will be output when the difference between the command pulse number of the host device and the servo motor movement (position deviation) is lower than the set value.
Pn262 Positioning completion range 0~ 1073741824 7 Command unit 0x0262 0x0263 Immediately In the position control, the servo motor positioning completion signal will be output when the difference between the command pulse number from the host device and the servo motor movement amount (position deviation) is lower than the set value that means the host device confirming positioning has been completed.
Pn264 Maximum position deviation threshold 1~ 1073741823 5242880 Command unit 0x0264 0x0265 Immediately When the motor operation does not match the instruction, by setting the appropriate Pn264 (maximum position deviation threshold), an abnormal condition can be detected and the motor can be stopped. Pn266 Excessive position deviation warning setting 10~100 100 % 0x0266 Immediately This parameter is used to set the position deviation excessive warning threshold. When the position deviation is greater than the product of the Pn264 (maximum position deviation threshold) and this parameter, an excessive position deviation warning will be generated.
Pn267 Position deviation alarm threshold when the servo is ON 1~ 1073741823 5242880 Command unit 0x0267 0x0268 Immediately This parameter is used to set the threshold for excessive position deviation alarm at the moment of servo ON. When the servo is ON, if the position deviation value exceeds this setting value, an excessive servo deviation alarm will be generated when the servo is ON.