When an over-travel occurs, the servo motor can be stopped by any of the following three methods: 2. Stop Mode Dynamic brake (DB) stop: By short-circuiting the electrical circuit, the servo motor can be quickly stopped. Deceleration stop: Decelerate to stop with the emergency stop torque (Pn053). Coast to a stop: Naturally stopped due to friction when the motor rotates. Coast mode: A state that naturally stops due to friction when the motor rotates. The servo motor status after stopping is divided into the following two types: Zero clamp mode: The state of the zero position is maintained in the position loop.
When the over-travel occurs, select the stopping method of the servo motor through Pn007. For details, please see parameter Pn007. ! It cannot decelerate to stop during torque control. Pn007 is set to DB or free running stop. After the servo motor stops, it enters the free running state. Cautions 3. Warning Checkout The over-travel warning function is a function that detects the over-travel warning (A.9A0) after the over-travel is entered when the servo is turned on. With this function, the servo unit can transmit the information on detecting the over-travel to the host device even if the over-travel signal is input instantaneously.
When using this function, please set Pn006=1 “Check over-travel warning”. The timing of check out over-travel warning: OFF ON Overtravel signal Overtravel warning AL9A0 Enable OFF does not check out warning Automatically clear warnings 1) A warning is detected when an over-travel occurs in the same direction as the instruction. 2) Warnings are not detected for over-travel in the reverse direction from the reference. Example: A warning will not be output for a forward instruction even if the N-OT signal (reverse run prohibited). 73 SD700 Series Servo Technical Manual Invalid Valid Invalid Normal Invalid Valid Invalid g