3) When there is no instruction, an over-travel warning in the forward or reverse direction will be detected. 4) When the servo is turned OFF, no warning will be detected even if it enters the over-travel status. 5) In the over-travel status, no warning is detected when the servo is switched from the servo OFF state to the servo ON status. 6) The warning I/O will remain output for 1 second after the over-travel status is released and will be automatically cleared afterwards. 5.1.3 Motor Rotation Direction The actual rotation direction of the servo motor can be switched by Pn002 without changing the polarity of the speed reference/position reference.
At this time, although the rotation direction of the motor is changed, the polarity of the output signal from the servo unit, such as the encoder frequency-divided pulse output, does not change. Pn002=0 in the factory setting (forward rotation direction) indicates that the counterclockwise rotation (CCW) is positive when looking at the servo motor cover. 5.1.4 Stop Mode Motor stop method can be selected by Pn004 1. Servo OFF and class 1 alarms • Dynamic brake (DB) stops and maintains DB status: By shorting the electrical circuit, the servo motor can be stopped in an emergency, and the DB status is maintained after stopping. • Dynamic brake (DB) stops and DB status is released:
By shorting the electrical circuit, the servo motor can be stopped in an emergency and the DB status is released after stopping. • Coast to a stop: Stopped naturally, with no control, by using the friction resistance of the servomotor in operation. ! When the servo motor stops or rotates at a very low speed, when dynamic braking stop is selected, it will be the same as the free running state. No braking force is generated as in the free running state. Cautions 2.
Stopping modes for type 2 alarms 74 SD700 Series Servo Technical Manual Function mode Parameter Range Default Uni Communicatio When t n address enabled Pn002 Motor rotation direction selection 0~1 0 - 0x0002 After restart Faces to the motor end: 0- Counterclockwise direction is positive. 1- Clockwise direction is positive.