VEICHI — SD700 User Manual 20230516

Servo enable signal signal (/S-ON) Brake chain signal (/BK) Motor energized An alarm occurs when the servo motor is locked. Regardless of this setting, the servo motor immediately enters the non-energized state.. Cautions ! At this time, the machine may move before the brake due to the delay of the brake action. 5.1.6 Regenerative Resistor Refer to “Regeneration Resistor Connection” for the wiring method. When connecting an external regenerative resistor, set parameters Pn012 and Pn013 according to the external resistance. The regenerative resistor capacity should be set to a value that matches the allowable capacity of the connected external regenerative resistor.

The setting differs depending on the cooling condition of the external regenerative resistor. • Self-cooling method (natural convection cooling): Set to 20% or less of the regenerative resistor capacity (W). • Forced air cooling: Set to 50% or less of the regenerative resistor capacity (W). Example: When the capacity of the self-cooling external regenerative resistor is 100W, the setting value is 100W Ч 20% = 20W. Therefore, set Pn012 = 2 (setting unit: 10W). 5.1.7 Overload This servopack can change the detection time of the overload warning (AL.910) and overload (continuous maximum) alarm (Er. 720).

However, it is not possible to change the overload characteristic and the detection value of the overload (instantaneous maximum) alarm (Er. 710). The factory defaults are: 1. Change of the time of detection of overload warning (AL.910) The factory overload warning detection time is 20% of the overload alarm detection time. The overload warning detection time can be changed by changing the overload warning value (Pn015). In addition, using it as an overload protection function corresponding to the system used can improve the security of the system. 77 SD700 Series Servo Technical Manual ON OFF Brake release Brake holding The motor is not powered Pn008 Motor energized Pn008