5.1.8 Multi-turn Absolute Encoder When using a multi-turn absolute encoder, an absolute value detection system can be constructed by a host device. With the absolute value detection system, it is not necessary to perform an origin return operation every time the power is turned on. In order to save the position data of the absolute encoder, a battery unit needs to be installed. Install the battery on the battery unit of the encoder cable with the battery unit. When using an encoder cable without a battery pack, install the battery in the host device. The battery voltage is 3.2V ~ 4.5V. If the battery voltage is lower than 3.2V, a battery under-voltage alarm (ER.830) will appear.
Generally, 3.6V/3.7V lithium batteries are used. Related parameters setting: 79 SD700 Series Servo Technical Manual Function Parameter Rang Default Unit Communication When enabled code e s address Pn040 Method to use absolute encoder 0~1 0 - 0x0040 After restart 0- Use an absolute encoder as an absolute encoder: If the motor is an absolute multi-turn encoder, setting this parameter to 0 can use the multi-turn absolute function. This function must be used with the encoder cable with battery, otherwise the servo will alarm (ER.810). 1- Use an absolute encoder as an incremental encoder:
When used as an incremental encoder, the power-off position won’t be recorded and warning or alarm, corresponding to multiple revolutions, won’t happen either when the battery is under- voltage or the drive is de-energized. Pn041 Absolute encoder battery warning/warn ing selection 0~1 0 - 0x0041 After restart 0- Set the low battery voltage as a fault: The driver powers up/resets for 4~9 seconds to monitor the battery status. Under-voltage will be reported as an under voltage alarm (Er. 830). Over time will not be detected. The drive cannot operate normally in a fault statue. 1- Set the low battery voltage as a warning:
Under-voltage (below 3.2V) will be reported as an under voltage alarm (Al.930). It will always monitor the battery voltage and can be self-recovery meanwhile enable running is out of restriction. Pn792 Absolute encoder operation 0~2 0 - 0x0792 After restart 0- No action. 1- Write motor parameters to encoder EEPROM: After modifying the motor parameters, you need to perform this operation to write the data to the encoder. 2- Clear multi-turn encoder laps: if you use it initially or replace or insert/remove the battery during power-down of the drive. After power on, an encoder backup alarm (Er. 810) will be reported.
This parameter is set to 2 in the servo disenable status (after setting it to 2, the parameter will be Automatically return to 0, this is a normal phenomenon) and it can only be cleared after re-powered. The alarm clearing will