2.Torque limit output signal The torque limit (/CLT) output is ON means the motor output torque is in the limit state. This signal can be used to confirm the status of the current torque limit of the motor. Refer to “Sequence Output Circuit” for the wiring method. Refer to “Switching Output Signal” for parameter setting. 3.Torque limit under voltage When the instantaneous power failure and the main circuit power supply voltage are insufficient for a short period of time, the main circuit DC voltage inside the servo unit is below the specified value, an under-voltage warning is detected, and the function for limiting the output torque can be selected. Related parameters are as below:

By combining this function with the setting function of the instantaneous stop holding time, when the power supply voltage is insufficient, it is possible to avoid the shutdown due to the alarm and continue the operation without performing the power restoration operation. Under-voltage warning, apply torque limit inside the servo unit. After receiving the under voltage warning release signal, the torque limit value is controlled within the servo unit according to the set release time. The logical timing is as follows:

81 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn045 Under-voltage function selection 0x00 ~ 0x02 0 - 0x0045 After restart 0 - No Detection of Main Circuit Descent Warning. 1 - Detection of Main Circuit Descent Warning. 2 - Detect main circuit down warning and perform torque limit. The relevant torque limit is matched with Pn046/Pn047. For details, refer to “Main circuit under-voltage torque limit”. Pn046 Torque limit when main circuit voltage drops 0 ~ 100 50 % 0x0046 Immediately According to the under voltage warning, it will impose the torque limit inside the servo unit.

Pn047 Torque limit release time when main circuit voltage drops 0 ~ 1000 100 ms 0x0047 Immediately After the under-voltage warning signal releases, the torque limit value is controlled within the servo unit according to the set time. For details, see “Under-voltage limit of the main circuit”.