can be obtained by the following formula: 1. Electronics gear ratio numerator (Pn204) set to 0, electronic gear ratio than the denominator (Pn206) set the value of the number of pulses corresponding to the motor running one lap, for example, Pn204 (numerator) set to 0, Pn206 (Denominator) set to 10000, it means that the upper computer (PLC, motion controller, etc.) send 10000 pulses servo motor turn one lap. 2. 0.001 ≤ electronic gear ratio (B/A) ≤ 83887 beyond this setting range, "Parameter Setting abnormality (Er.040) alarm" (for 23 bit encoder). Cautions ! 5.2.3 Deviation Clearance The deviation clear signal (/CLR) is the input signal to clear the servo unit deviation counter.
84 SD700 Series Servo Technical Manual Mechanical system Ball screw Rotary table Belt + Pulley Command unit: 0.001mm Load shaft 24 bit encoder Ball screw lead: 6mm Command unit: 0.01° Reduction Load shaft ratio1:100 24 bit encoder Command unit: 0.005mm Load shaft Reduction Pulley dia: 100mm ratio 1:50 24 bit encoder Steps Content 1 Machine specification Ball screw lead: 6mm Reduction ratio: 1/1 Rotation angel per turn: 360° Reduction ratio: 1/100 Pulley dia: 100mm (Pulley circumference 314mm) Reduction ratio:
1/50 2 Encoder resolution 8388608 (23 bit) 16777216 (24 bit) 131072 (17 bit) 83886708 (23 bit) 16777216 (24 bit) 131072 (17 bit) 8388608 (23 bit) 16777216 (24 bit) 131072 (17 bit) 3 Command unit 0.001mm (1mm) 0.01° 0.005mm (5mm) 4 Load shaft movement in 1 rotation (command unit) 6mm/0.001mm = 6000 360° /0.01° = 36000 314mm/0.005mm = 62800 5 Electronic gear ratio 6 Parameters Pn204: 8388608 Pn204: 838860800 Pn204: 419430400 Pn206: 6000 Pn206: 36000 Pn206: 62800