VEICHI — SD700 User Manual 20230516

See the “Deviation Clearance” for details on the pulse amplitude of the clear signal. In position control, the positional deviation remains unchanged when the servo motor is stopped due to the travel limit. ! When the position mode is running, the servo motor stops due to the travel limit. If the upper computer continues to send pulses at this time, the position deviation will keep increasing and the position deviation will not be cleared automatically, which may cause the motor to fly when the travel limit is excluded.

Cautions 5.2.4 Command Pulse Prohibition The command pulse inhibition (/INHIBIT) function is a function that prohibits the command pulse input from being counted during position control. When this function is enabled, the servo unit enters a state where it cannot receive the command pulse input. 1. Configuration of Command Pulse Prohibition The signal is not configured in the factory default switch configuration. Therefore, the pin number configuration (0x0D) needs to be performed by parameters Pn601 ~ Pn609. 2. Command pulse inhibited wiring The command pulse disable signal is a universally configurable digital input. See “Sequence Input Circuit” for wiring details.

5.2.5 Positioning Approach When positioning is close to (/NEAR) position control, the host device may receive the positioning proximity signal before confirming the positioning completion signal, so as to prepare for the sequence of actions after the positioning is completed. In this way, the time required to complete the positioning can be shortened. This signal is usually used in pair with the positioning completion signal. Refer to the “Positioning completed” instruction for the positioning completion signal. 1. Positioning close to the configuration The signal is not configured in the factory default digital output configuration.

Therefore, the pin number configuration (0x08) needs to be performed by parameters Pn613 ~ Pn615. When the difference between the command pulse number of the host device and the movement amount of the servo motor (position deviation) is lower than the setting value of Pn260 (position proximity signal width), the signal is output when the positioning close output condition is satisfied. 2. Locating close wiring The positioning proximity signal is a universally configurable digital output. See “Sequence Output Circuit” for wiring details. 86 SD700 Series Servo Technical Manual 5-Cleared in case of servo OFF, alarm and limit.