2. Positioning completion wiring The positioning completion signal is a universally configurable digital output. For wiring details, refer to “Sequence Output Circuit”. Example of optocoupler circuit Controller Example of relay circuit Controller 5V~30V 5.2.7 Command Pulse Input Magnification Switching The ON/OFF of the override input switching signal (/PSEL) of the command pulse input switches the input override of the position command pulse to 1 and n times (n = 1 to 100). The switching of the override can be confirmed by the command pulse input of the override switching output signal (/PSELA). Please switch the command pulse magnification while the position command pulse is 0.
If the position command pulse is not 0, the servo motor may cause a position error or cause a position loss. 1. Configuration of command pulse input magnification switching The signal is not configured in the factory default digital input configuration. Therefore, the pin number configuration (0x10) needs to be performed by parameters Pn601 ~ Pn609.
88 SD700 Series Servo Technical Manual S ervo driver SEN OCZ GND 5V T wisted pair S ervo driver SEN OCZ GND T wisted pair Function Parameter Range Default Unit Communication When code address enabled Pn203 Command pulse input magnification 1~ 100 1 x1 times 0x0203 Immediately Set the command pulse input magnification value to be used in conjunction with ON/OFF of the command pulse magnification switching signal for switching the position command pulse input magnification to 1 and the parameter setting multiple. Note: The input pulse frequency is too low. If the value is set too large, the speed may not be steady.