Valid Command pulse input multiplier switching input signal /PSEL Command pulse input multiplier switching output signal /PSELA Below 4ms Below 4ms Internal action The command pulse input override signal is a universally configurable digital input. See “Sequence Input Circuit” for wiring details. 2. Command pulse input magnification switching wiring 5.2.8 Smooth Settings The command pulse input is filtered to make the rotation of the servo motor smoother. This function is more effective in the following situations: The host device that issued the command does not perform acceleration / deceleration. When the instruction pulse frequency is extremely low.
When the position command smoothing function is set, the system response may be affected. Please use it reasonably. The filter-related parameter settings are as follows: 89 SD700 Series Servo Technical Manual r Invalid Valid r Invalid A x1 Pn203 x1 Function Parameter Range Default Unit Communication When code address enabled Pn211 Position command low- pass filter time constant 0~655 0 ms 0x0211 After stop This parameter is used to set the time constant of the first-order low-pass filter corresponding to the position command and it can reduce the mechanical shock in the case of abrupt changes in the input pulse command frequency by setting this parameter.
If set too large, the servo response will slow down. Pn212 Moving average filtering time of position command 0~1000 0 ms 0x0212 After stop This parameter is used to set the time constant of the moving average filter of the corresponding position instruction. It can reduce the mechanical shock in the case of abrupt changes in the input pulse command frequency by setting this parameter. If set too large, the servo response will slow down.