VEICHI — SD700 User Manual 20230516

The difference between the position command low-pass filter time constant and the position command's moving average filter time is shown below: Low pass filter Moving average filter Before filtering 100% Position instruction Before filtering Position instruction 100% After filtering 63.2% Pn211 Pn211 Time Pn212 Pn212 Time Moving average filter Position instruction Pn212 Before filtering After filtering 5.2.9 Frequency-division Output Pn212 Time The encoder frequency-divided pulse output is a signal that is output to the outside in the form of a two-phase pulse (phase A, phase B) with a phase difference of 90° after processing the signal from the encoder inside the servo unit.

Used as position feedback in the host device. Frequency-division pulse output parameter configuration How to set the encoder frequency pulse output as follows: 90 SD700 Series Servo Technical Manual % After filt 36 Af Function Parameter Range Default Unit Communication address When code enabled Pn070 Encoder divider pulses 16~ 4194304 2048 0x0070 After restart The number of pulses per cycle from the encoder is divided by frequency in accordance with the set value of this parameter. Please set it according to the system specifications of the machine and host device. Pn072 Divided frequency output reversed 0~1 0 - 0x0072 After restart