The number of pulses per revolution from the encoder is processed inside the servo pack and then divided down and output to the set value of Pn070. 1. Frequency division pulse The encoder's number of divided pulse outputs is set according to the system specifications of the machine and the host device. The setting of frequency division pulse number of encoder will be limited by the resolution of encoder. The maximum output frequency of frequency division pulse of encoder shall not exceed 4MHz (after 4 times frequency), as shown in the table below: Output example:
When Pn070=16 (16 pulses per revolution), an example of the output of the encoder-divided pulse output A-phase (PAO) signal and the encoder-divided pulse output B-phase (PBO) signal is shown below. PAO PBO 1 Resolution Pn070=16 2. Frequency division output reversed 91 SD700 Series Servo Technical Manual A/B pulse phase sequence logic when setting forward/reverse: 0- Don’t revert the pulse output: When forward, A leads B. 1- 1- Revert the pulse output: When forward, B leads A .
Pulse Number of Encoder Encoder Resolution Setting Upper Limit of motor Frequency Devision (pulse/r) increment 17 bits 20 bits 23 bits Speed ( r/min) 16~16384 1 o o o 6000 16386~32768 2 o o o 3000 32772~65536 4 o o o 1500 65544~131072 8 o o o 750 131088~262144 16 - o o 375 262176~524288 32 - o o 187 524352~1048576 64 - o o 93 1048704~2097152 128 - - o 46 2097408~4194304 256 - - o 23