Motor NOTE: Motors used on wood working tools are particularly susceptible to the accumulation of sawdust and wood chips and shouId be blown out or "Vacuumed" frequently to prevent interference with normal motor ventilation Trouble Probable Cause Remedy FExcessive Noise 1 Motor 1 Have motor checked by qualified service technician Repair service is available at your nearest Sears store. Motor fails to develop full power NOTE: Low Voltage:
(Power output of motor decreases rapidly with decrease in voltage at motor terminals For example, a reduction of 110% in voltage causes '.a reduction of 19% in t Circuit overloaded with lights, appliances and other motors 2 Undersize wires or circuit too 1 Do not use other appliances or motors on same cir- cuit when using the saw 2. Increase wire sizes, or reduce length of wiring. See "Motor Specifications and electrical Requirements" section Request a voitage check from the power company long 3.
General overloading of power 3 company facilities r (in some sections of the country, demand for electrical power may exceed the capacity of existing generating and distribu- tion systems ) 4 Incorrect fuses of circuit break- era in power line maximum power output of which the motor is capable, and a reduc- tion of 20% in voltage causes a reduction of 4. Install correct fuses or circuit breakers 36% in maximum power output.) Motor starts slowly or fails to come up to full speed 1. Low voltage 1. 2 Windings burned out or open 2 3 Starting relay not operating 3 Request voltage check from the power company Have motor repaired or replaced.
Have relay reptaced Motor overheats 1 Motor overloaded 1 2 Improper cooling (Air circulation 2 restricted through motor due to sawdust, accumulating inside of saw ) Feed work slower into blade Clean out sawdust to provide normal air circulation through motor See "Maintenance" and "Lubrication" section Relay will not operate 1. Burned contacts (due to 1, extended hold-in periods caused by low line voltage, etc.,) 2. Saw not in upright position 2. 3. Loose or broken connectors. 3 Have relay replaced and request a voltage check from the power company Place saw in upright position. Have wiring checked and repaired. Motor stalls (resulting in blown fuses or tripped circuit breakers) 1.
Starting relay not operating, 1 2 Voltage too low to permit motor 2. to reach operating speed 3 Fuses or circuit breakers do not i3 have sufficient capacity. Have relay replaced Request voltage check from the power company Install proper size fuses or circuit breakers. Frequent opening of fuses or circuit breakers 1. Motol overloaded j l 2 Fuses or circuit breakers do not 2 have sufficient capacity 3. Starting relay not operating _3 (motor does not reach speed.) Feed work slower into blade Install proper size fuses or circuit breakers Have relay replaced. 46