Smart IP43 Charger Manufacturer IP43 — 8.2. Expert mode settings

Smart IP43 Charger C. Absorption i. Absorption duration The absorption duration setting allows selection between adaptive absorption time (calculated based on the bulk time / level of discharge) or a fixed absorption time. ii. Maximum absorption time / Absorption time The maximum absorption time / absorption time setting enables the maximum adaptive absorption time or the fixed absorption time to be configured (depending if adaptive or fixed absorption time is selected). Note that regardless if adaptive or fixed absorption time is selected, the absorption phase can end early based on the tail current setting (if enabled). iii.

Tail current The tail current setting enables the absorption stage to be ended early based on charge current. If the charge current drops below the tail current threshold for one minute, the absorption stage will immediately end and the charger will move to float or storage stage. iv. Repeated absorption The repeated absorption setting enables the elapsed time between each automatic refresh charge cycle (1h in absorption stage) to be configured. Repeated absorption is enabled by default and can be disabled which results in the battery staying in storage mode indefinitely. D. Recondition i.

Recondition current percentage The recondition current percentage is used to establish the charge current limit while the charger is in recondition stage; the percentage is relative to the configured Maximum charge current. The charger will limit charge current to this lower level while in recondition stage. ii. Recondition stop mode The recondition stop mode setting allows selection between the recondition stage being ended upon the battery voltage reaching the recondition stage voltage setpoint or a fixed time period. iii.

Maximum recondition duration The recondition time setting enables the maximum recondition time or the fixed recondition time to be configured (depending on the recondition stop mode selected). iv. Manual recondition Manual recondition can be started by selecting on the START NOW button. The duration of the recondition cycle is limited to a maximum of 1 hour. Page 59 Advanced Configuration