SPRUT — ANALYSIS AND DESIGN OF FLAT SLABS USING VARIOUS CODES

For slabs 200 mm thick or greater reference should be made to Section 7.3.3 of the Eurocode. Spacing of punching shear reinforcement Where punching shear reinforcement is required the following rules should be observed. 1. It should be provided between the face of the column and kdinside the outer perimeter where shear reinforcement is no longer required. k is 1.5, unless the perimeter at which reinforcement is no longer required is less than 3 d from the face of the column. In this case the reinforcement should be placed in the zone 0.3 d to 1.5dfrom the face of the column. 2. There should be at least two perimeters of shear links. 3.

The radial spacing of the links should not exceed 0.75 d 4. The tangential spacing of the links should not exceed 1.5 d within2d of the column face. 5. The tangential spacing of the links should not exceed 2d for any other perimeter. 6. The distance between the face of the column and the nearest shear reinforcement should be less than 0.5d 36