Design strips Column strip is a design strip with a width on each side of a column centerl ine equal to 0.25 l 2 or 0.25 l 1 , whichever is less. Middle strip is a design strip bounded by two column strips. A panel is bounded by column, beam, or wall centerlines on all sides. Column head The upper supporting part of a column is enlarged to form the column head. The diameter or the column head is made 0.20 to 0.25 of the span length. Total factored static moment for a span Total factored static moment for a span shall be determined in a strip bounded laterally by centerline of panel on each side of centerline of supports.
Absolute sum of positive and average negative factored moments in each direction shall not be less than. 2 2 0 8 u n w l l M u w =load per unit area acting on the slab panel n l =Clear span n l shall extend from face to face of columns, capitals, brackets, or walls. Value of l n shall not be less than 0.65 1 l . Circular or regular polygon shaped supports shall be treated as square supports with the same area. 2 l =When the span adjacent and parallel to an edge is being considered, the distance from edge to panel centerline shall be substituted for 2 l . In an interior span, total static moment 0 M shall be distributed as follows:
Negative factored moment .................................0.65 Positive factored moment ...................................0.35 41