A+ Server 1122GG-TF User's Manual Checking the Air Flow Checking the Air Flow in the Chassis Make sure there are no wires or other objects obstructing the airflow in and out of the server. Pull all excess cabling out of the airflow path or use shorter cables. Do not operate the server without drives or drive trays in the drive bays. Use only recommended server parts. The control panel LEDs inform you of the overall system status. See “Chapter 4 System Interface” for details on the LEDs and the control panel buttons. 6-5 Installing Expansion Cards The SC118G chassis includes I/O slots for four full-height, full-length expansion cards, although the 1122GG-TF server supports only two.
Alternatively, the server can be configured for two double-width, high-end graphics processor units (GPUs). In addition the chassis and serverboard support one low-profile expansion card Figure 6-6. Rear Expansion Slots One Low-Profile GPU Slot Optional Double-Width, GPU Slot Expansion Slot Optional Double-Width, Full-Height, Full-Length Expansion Slots 6-8