Supermicro SuperServer 1015B-M3 — Supermicro SuperServer 1015B-M3 User's Manual PDF (Revision 1.0)

S UPER S ERVER 1015B-M3 User's Manual Redundant Power Supply Fail Connect a cable from your power supply to the header at J3P to pro- vide warning of a redundant power supply failure. This warning signal is passed through the PWR_LED pin to indicate a power failure on the chas- sis. See the table on the right for pin defi nitions. Note: This feature is only available when using Supermicro redundant power supplies. Alarm Reset If three power supply modules are installed, the system can notify you when any of the three fails. Connect JAR to a micro-switch to enable you to turn off the alarm that is activated when a power module fails. See the table on the right for pin defi nitions.

I-Button The I-Button, located above the LSI chip on the motherboard, is a computer chip enclosed in a durable stainless container to enable RAID 5 under Software RAID mode. See the table on the right for pin defi nitions. 5-18 PWR Supply Fail Alarm Pin Defi nitions (J3P) Pin# Defi nition 1 PWR 1: Fail 2 PWR 2: Fail 3 PWR 3: Fail 4 Signal: Alarm Reset Alarm Reset Pin Defi nitions (JAR) Pin Setting Defi nition Pin 1 Ground Pin 2 Alarm Reset I-Button Pin Defi nitions Pin# Defi nition 1 Ground 2 GPIO1 3 Ground