Supermicro 1018D-73MTF — SUPERSERVER 1018D-73MTF — User's Manual

Chapter 5: Advanced Motherboard Setup NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network activities for LAN 1 and LAN2. Refer to the table on the right for pin definitions. Overheat (OH)/Fan Fail/Front UID LED Connect an LED cable to pins 7 and 8 of JF1 to provide warnings of overheat, fan failure or power failure. TRefer to the table on the right for pin definitions. Reset Button The Reset Button connection is located on pins 3 and 4 of JF1.

Attach it to a the hardware Reset Button on the computer case. Refer to the table on the right for pin definitions. Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

5-13 GLAN1/2 LED Pin Definitions (JF1) Pin# Definition 9 Vcc 10 NIC 2 Link/Acitivty LED 11 Vcc 12 NIC 1 Link/Acitivty LED OH/Fan Fail/ PWR Fail/Blue_UID LED Pin Definitions (JF1) Pin# Definition 7 Vcc 8 Red LED-Cathode/OH/Fan Fail/ _ Power Fail OH/Fan Fail/PWR Fail LED Status (Red LED) State Definition Off Normal On Overheat Flashing 1 Hz Fan Fail Flashing 1/4 Hz Redundant Power Supply Fail Reset Button Pin Definitions (JF1) Pin# Definition 3 Reset 4 Ground PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR LED Status