Supermicro 5038MD-H24TRF — Supermicro SuperServer 5038MD-H24TRF User's Manual PDF

Chapter 4: Motherboard Connections BMC Enable/Disable JPB1 is used to enable or disable the BMC (Baseboard Management Control) chip (P1-JPB1 for Node 1, P2-JPB1 for Node 2) and the onboard IPMI connection. This jumper is used together with the IPMI settings in the BIOS. LAN Ports Enable/Disable Jumper JPL1 enables or disables Ethernet LAN ports on the motherboard. P1-JPL1 enables and disables P1-LAN1 and P1-LAN2. P2-JPL1 enables and disables P2-LAN1 and P2-LAN2. The default setting is Enabled. Management Engine (ME) Recovery Set jumpers P1-JPME1/P2-JPME1 to select ME Firmware Recovery mode for Node 1 (P1- JPME1) or Node 2 (P2-JPME1).

ME Recovery limits system resource for essential function use only without putting restrictions on power use. In the single-operation mode, online upgrade will be available via Recovery mode. Manufacturer Mode Select Close the Manufacturer Mode (ME) Select Jumper P1-JPME2 (for Node 1) or P2-JPME2 (for Node 2) to bypass SPI flash security and force the system to use the Manufacturer mode. ME mode allows the user to flash the system firmware from a host server to modify system settings of a machine at a remote location.

41 BMC Enable Jumper Settings Jumper Setting Definition Pins 1-2 BMC Enabled Pins 2-3 Disabled GbE LAN Enable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled (Default) Pins 2-3 Disabled Management Engine Recovery Jumper Settings Jumper Setting Definition Pins 1-2 Normal Pins 2-3 ME Recovery Manufacturer Mode Jumper Settings Jumper Setting Definition Pins 1-2 Normal Pins 2-3 Manufacturer Mode