Supermicro SuperServer 8060 — Supermicro SuperServer 8060 User Manual PDF – 4U Quad Xeon Server Guide

S UPER S ERVER 8060 Manual PWR P Header A four-pin connector from the power supply connects to the PWR P header on the motherboard to notify you in the event of a power supply failure. If your sys- tem does not have three power supply units, you should disable this with JP55 to prevent false alarms. See Table 5-20 for the pin definitions of the PWR P header. (The power supplies are num- bered from top to bottom.) Table 5-20 PWR P Header Pin Definitions SLED (SCSI LED) Indicator Table 5-21 SLED (SCSI LED) Pin Definitions The SLED connector is used to pro- vide an LED indication of SCSI ac- tivity. Refer to Table 5-21 for con- necting the SCSI LED. 5-8 DIP Switch Settings DIP Switch 1:

Core/Bus Ratio Table 5-22 CPU Core/Bus Ratio Selection (DIP Switch1) Two DIP Switches labeled SW1 and SW2 are located on the S2QE6. Each has four individual switches. SW1 is used to set the core/bus ratio. The example on the right will show you which CPU 550 MHz = 100 MHz x 5.5 CPU Speed = Bus Freq.

x Ratio 5-20 Pin Number Definition 1 2 3 4 P/S1 signal P/S2 signal P/S3 signal Reset Pin Number Definition 1 2 3 4 Positive Negative Negative Positive CPU Core/ Bus Ratio S W 1 #4 S W 1 #3 S W 1 #2 S W 1 #1 2.0 3.0 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 O N O N O N O N O N O N O F F O F F O F F O F F O F F O N O N O F F O F F O F F O F F O N O N O N O N O F F O N O F F O N O N O F F O F F O N O N O F F O F F O N O N O N O N O F F O N O F F O N O F F O N O F F O N