SuperStorageSystem 5049P-E1CTR36L User's Manual Power SMB (I 2 C) Header The Power System Management Bus (I 2 C) connector (JPI 2 C1) monitors the power supply, fan, and system temperatures. Refer to the table below for pin definitions. 4-pin BMC External I 2 C Header A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I 2 C connection on your system. Refer to the table below for pin definitions. Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened.
Refer to the table below for pin definitions. NVMe I 2 C Header Connector JNVI 2 C1 is a management header for the Supermicro AOC NVMe PCI-E peripheral card. Please connect the I 2 C cable to this connector. VRM SMBus Header JVRM1 is a voltage regulator module (VRM) SMBus header. Use this header to program the CPU and memory VRM controllers. 46 Power SMB Header Pin Definitions Pin# Definition 1 Clock 2 Data 3 PMBUS Alert _ 4 Ground 5 +3.3V External I2C Header Pin Definitions Pin# Definition 1 Data 2 Ground 3 Clock 4 No Connection Chassis Intrusion Pin Definitions Pin# Definition 1 Intrusion Input 2 Ground