US Army Developmental Test Command TOP 1-2-622 — Test Setup #1

Downloaded from https://www.everyspec.com TOP 1-2-622 11 September 2009 3. Provided are some possible measurements and calculations. Table D-1 provides example reduced VEMP test data for a system with three EIDs. Graph D-1on the following page provides a frequency and time corrected induced current. Graph D-2 provides the energy delivered to the EID by the VEMP pulse. The energy is acquired by rectifying the induced current, then calculating instantaneous power at each data point utilizing the EID impedance and finally integrating over time to convert to energy. Table D-1.

EED Induced Currents D-2 Test Root Total Total point Peak I Peak Peak Rectified Action Energy Energy ID Orient Shot# (Amp) Derivative Impulse Impulse Integral 1 Ohm 3 Ohms 1 1-front 5166 0.0858 8.56E+07 1.66E-10 4.04E-09 1.18E-05 1.38E-10 4.15E-10 2 1-front 5167 0.1030 1.29E+08 4.80E-10 7.44E-09 1.80E-05 3.26E-10 9.77E-10 3 1-front 5169 0.1551 1.63E+08 2.37E-10 5.21E-09 1.69E-05 2.85E-10 8.55E-10 1 2-front 5170 0.1473 1.74E+08 1.79E-10 6.73E-09 2.01E-05 4.03E-10 1.21E-09 2 2-front 5171 -0.1471 1.72E+08 1.03E-09 8.22E-09 2.12E-05 4.51E-10 1.35E-09 3 2-front 5173 0.1012 9.85E+07 1.19E-10 3.64E-09 1.07E-05 1.14E-10 3.42E-10 1 2-back 5175 0.0125 1.98E+07 2.04E-11 6.42E-10 1.72E-06 2.94E-12 8.83E-12 2 2-back 5176 0.0142 2.12E+07 1.92E-11 7.52E-10 1.94E-06 3.78E-12 1.13E-11 3 2-back 5177 -0.0168 2.25E+07 4.15E-11 6.63E-10 2.00E-06 4.00E-12 1.20E-11 1 2-side 5180 -0.0343 5.30E+07 8.81E-11 1.13E-09 3.43E-06 1.18E-11 3.54E-11 2 2-side 5181 0.0459 7.25E+07 1.44E-10 2.47E-09 6.59E-06 4.34E-11 1.30E-10 1 2-side 5182 -0.0324 5.06E+07 9.51E-11 1.12E-09 3.40E-06 1.16E-11 3.47E-11 3 2-side 5183 -0.0506 6.09E+07 7.10E-11 1.75E-09 5.46E-06 2.99E-11 8.96E-11 1 2-front 5184 -0.0553 8.63E+07 1.81E-10 1.67E-09 5.20E-06 2.71E-11 8.12E-11