Downloaded from https://www.everyspec.com TOP 1-2-622 11 September 2009 Figure E-1. Probe Adapter. 2. FIBER OPTIC DATA LINKS: In general the facility calibration of data links is performed as matching pairs (i.e. the optical transmitter and the optical receiver are matched into a data link). These matched pairs are always to be used together during data acquisition. The DATA links are available from several manufactures one of the most common is NANO-FAST. The link is connected to a network analyzer. The network analyzer output feeds both the forcing function and the reference measurement and measures the voltage output of the link.
This forcing function is driven across the frequency spectrum for which the link is being calibrated. The link voltage output is divided by the measured reference voltage across the frequency range being calibrated. The result is the transfer function of the link versus frequency for which the units are volts/volt. Experience has indicated that 400 measurements across the frequency spectrum tend to be adequate for calibration. This frequency calibration is used as follows: The data produced by the sensor is input to the fiber transmitter and received by the fiber receiver and the receiver output voltage is recorded on fast oscilloscopes as voltages in the time domain.
The recorded data then requires correction for the link transfer function (frequency response). This is accomplished using convolution in the time domain. The process however takes place in the frequency domain since in the frequency domain convolution reduces to simple point by point division. The process for a link is that the recorded time domain waveform is converted to the frequency domain using Fast Fourier transforms (FFT). The resulting frequency data is then divided on a per frequency basis by the link transfer function at that frequency, interpolation between probe calibration frequency points is used to match the exact frequency resulting from the FFT.
Once the convolution has taken place the FFT is now corrected for the link response and the inverse FFT results in the corrected time response. 3. FIBER: The fiber is not calibrated versus frequency sine it possesses no elements which would result in a change in frequency spectrum transmission. Most fiber link provide for a standard signal being transmitter over the fiber to verify its acceptability. This measurement being unacceptable indicates two potential faults; the first is that the ends of the fiber are dirty and the second is that the fiber is broken. E-2