Тексел ТХ01-RS — 7.3 Output settings

Figure 7.9 – Generating of the output signal in the U-controller mode (output of type У) When the output works as a recorder ( oUtdAC = 3), the following occurs: • comparing the measured value with the set values of the lower limit of the recording range and the value of the entire recording range; • issuing an analog signal to the corresponding output in the form of a current from 4 to 20 mA (for output type И) or voltage from 0 to 10 V (for output type У), which can be fed to a recorder or other recording device. The principle of generating the output signal is shown in Figures 7.10 and 7.11 .

When the output is working as a recorder, the lower and upper limits of registration should be set in the Lor and Hir parameters. NOTICE When the measured value goes beyond the recording range, the error level is set at the output: 20.2 mA (for type И output), more than 10.5 V (for type У output). When oUtdAC = 0, the operation control of the analog output is disabled. The output status is set by oFFdAC parameter. 46