HP — Nozzle Health

Reading the Advanced Diagnostic Print Results For the thetaZ and VLS diagnostics the dark band of the print is the area to check. In the following example print the lightest segment of the dark band is positioned on the -1 column. Dark band „ If any of the printheads are misaligned beyond the ±1 dot row range, perform a Printhead Alignment. see Aligning Printheads , Page 1-66 „ If a Printhead Alignment does not correct the problem, replace the bad printhead. If the customer is using non-HP media and after the Image Quality Test you still have the same image quality problems, change to genuine HP media and repeat the Image Quality Test.

The best alignment calibration is obtained using HP Photo Paper. Nozzle Health The print contains three separate parts. a b c a The Variable Frequency Nozzle health plot with odd/even nozzles separation. This is used to detect misdirected or weak nozzles, nozzles not working correctly at all frequencies, or even Gloss Enhancer (GE) color problems. This plot might show defects with the printheads that are not visible in the Service Image Quality Diagnostic Print. Look at the color bars and lines Designjet Z Series — Service Manual 1-36