HP — Force Drop Detection

Reading the Advanced Diagnostic Print Results to check if you see any missing parts of the plot, banding or white streak in them. b Inspector measuring tool test plot. Test b should NOT be used by Service Engineers. c Nozzle Print Test which is also part of the Image Quality Service Plot. This test is designed to check that the Printhead nozzles print correctly. The test prints out every single nozzle of each Printhead. No error hiding or Printhead Alignment algorithm is applied. For each Printhead, you can see both the adjacent and the consecutive nozzles. This is what you would see in the Nozzle Print Test part if there are nozzles not printing correctly:

1 On the right of each Printhead Nozzle test, there is a series of numbered stepped diagonal lines. If one or more of the nozzles are malfunctioning or mis-positioned, you will see that the stepped lines are broken or misdirected in one or more places. 2 On the left of each Printhead Nozzle test, there is a series of horizontal straight lines. If one or more nozzles are misdirected there will be unequal spaces between the corresponding lines. Corrective Action for Nozzle Defects If the printer has nozzle defects, it does not mean that you will not get perfect print quality results. The printer has automatic procedures to hide many nozzle defects.

1 Recover the Printheads using the option through the Front Panel (Main menu/Image quality maintenance/clean printheads). 2 Reprint the Nozzle Print test to check that the defective nozzles have been corrected. 3 If the problem continues, replace the defective Printhead. Force Drop Detection If the Nozzle Print Test plot has persistent white point banding in only one color that cannot be fixed with a printhead recovery, you can use this option to resolve the problem by resetting the nozzle health data base so that all nozzles are assumed to be correct. Once the nozzle health data base has been reset drop detection is forced.

The normal cause of this white point banding in a single color is the incorrect detection of failed nozzles by the drop detector. Designjet Z Series — Service Manual 1-37