beckhoff TS1110 — 8 FAQs (frequently asked questions)

FAQs (frequently asked questions) 2. Exit the system manager process. 3. If the system manager process does not exit, another router cleanup should be initiated. This should terminate the system manager process! Error Message: "The PlcControl symbol file for the project 'XXX' has not been found. The system manager configuration must be corrected before it can be used!" Problem: The symbol file (*.tpy) specified in the system manager could not be found! Solution: Reconnect the symbol file in the system manager configuration and rescan the symbol ("Rescan"). The newly created simulation PLC project does not contain any inputs or outputs. Problem:

The following conditions must be fulfilled to create the allocated variables: The original PLC projects must contain allocated variables, which can then be exported into the simulation PLC project. The simulation PLC symbols must be used in the simulation project The simulation PLC project must have been compiled. TS1110 80 Version: 1.0