beckhoff TwinCAT 2 — 5.1 Menu of the TwinCAT System Service

User Interface Ports Number of registered ports Server Ports which are occupied by the TwinCAT servers Transports Internal only Mail debugging In conjunction with the TwinCAT Maildebugger, it is possible to record the entire TwinCAT message traffic. In this case, it must be noted that the message traffic is slowed down by the additional messages. The Mailde- bugger is not part of the TwinCAT standard scope of delivery. Cleanup Ports in the router which originate from no longer functional programs are released again with the "Cleanup" function of the router. This function is particularly appropriate in the development phase of the applications. System:

If the TwinCAT system is not configured for an automatic start, the start can also be performed manually via the context menu. The configuration of the automatic start is carried out with the TwinCAT System Control. Only the functions which are appropriate in the current operating state are released in the context menu. In the example, the TwinCAT system is in the Stop state, which means that only Start is possible. The functions in detail: Start: The TwinCAT system is started. All entered TwinCAT servers are loaded and initialised. The TwinCAT I/O subsystem is parameterised by the Twin-CAT I/O Manager in accordance with the configuration.

All entered run time systems of the PLC subsystem are initialised. If a boot project is entered for a run time system, this is loaded and the PLC program is started. The remaining (retain) data is also loaded in accordance with the configuration. The boot project is generated with the TwinCAT PLC Control. The start behaviour (boot project, data remanence) of the PLC run time system can be configured via the TwinCAT System Control. Stop: The TwinCAT system is stopped. All entered TwinCAT servers are shut down and unloaded. After the TwinCAT system stops, there is only the TwinCAT Message Router still in the memory. The TwinCAT system can now be restarted via the "System -> Start". Restart:

The TwinCAT system is first stopped and is then restarted. This function is useful in the event of changes to the system configuration, because in this way the configuration is again loaded by the restart. The TwinCAT Message Router can represent its internal memory admini-stration and port administration for diagnosis. This service can be called up via the context menu. IO: The TwinCAT I/O subsystem can be reset via the TwinCAT System Ser-vice. For this, the corresponding function must be selected in the context menu. The reset applies to all connected field bus systems. For details, also refer to the documentation of the TwinCAT I/O Manager. System 18 Version: 1.2