Overview of NC errors TwinCAT 28 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4307 17159 parameter "Fast manual velocity not allowed" The value for the fast manual velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4308 17160 parameter "High speed not allowed" The value for the high speed is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4309 17161 parameter "Acceleration not allowed" The value for the axis acceleration is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s 430A 17162 parameter "Deceleration not allowed" The value for the axis deceleration is not allowed. Value range: [0.0, 1000000.0] Unit: e.g.
m/s/s 430B 17163 parameter "Jerk not allowed" The value for the axis jerk is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s 430C 17164 parameter "Delay time between position and velocity is not allowed" The value for the delay time between position and velocity ("idle time compensation") is not allowed. Value range: [0, 0.1] Unit: s 430D 17165 parameter „Override-Type not allowed“ The value for the velocity override type is not allowed. Type 1: With respect to the internal reduced velocity (default value) Type 2: With respect to the original external start velocity Value range: [1 ... 4] Unit: 1 430E 17166 parameter "NCI:
Velo-Jump-Factor not allowed" The value for the velo-jump-factor ("VeloJumpFactor") ist not allowed. Value range: [0, 1000000] Einheit: 1 430F 17167 parameter "NCI: Radius of tolerance sphere for the auxiliary axes is invalid" It was tried to enter an invalid value for the size of the tolerance sphere. This sphere affects only auxiliary axes! Value range: [0, 1000] Unit: e.g. mm 4310 17168 parameter "NCI: Value for maximum deviation for the auxiliary axes is invalid" It was tried to enter an invalid value for the maximum allowed deviation. This parameter affects only auxiliary axes! Value range: [0, 10000] Unit: e.g.
mm 4312 17170 parameter "Referencing velocity in direction of cam not allowed" The value for the referencing velocity in the direction of the referencing cam is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4313 17171 parameter "Referencing velocity in sync direction not allowed" The value for the referencing velocity in the direction of the sync pulse (zero track) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4314 17172 parameter "Pulse width in positive direction not allowed" The value for the pulse width in the positive direction is not allowed (pulsed operation). The use of the pulse width for positioning is chosen implicitly through the axis start type.
Pulsed operation corresponds to positioning with a relative displacement that corresponds precisely to the pulse width. Value range: [0.0, 1000000.0] Unit: e.g. mm