Knowledge Base Bit-masks for axis enable information These masks are to be used by the application to provide enable signals in nDeCtrlDWord in ST_TcHydAxRtData. Error Codes These constants are to be used for the outputs of ErrorID from function blocks and for nErrorCode in ST_TcHydAxRtData. PLC Library Hydraulics 236 Version: 1.4 Constant Description dwTcHydDcDwCtrlEnable Controller enable. This enable is a precondition for the output of control value and controller outputs. dwTcHydDcDwFdPosEna Advance movement enable in positive direction. This enable is a precondition for the output of control value and controller outputs in the direction of increasing values of position.
dwTcHydDcDwCtrlPosEna Combination of dwTcHydDcDwCtrlEnable and dwTcHydDcDwFdPosEna. dwTcHydDcDwFdNegEna Advance movement enable in negative direction. This enable is a precondition for the output of control value and controller outputs in the direction of decreasing values of position. dwTcHydDcDwCtrlNegEna Combination of dwTcHydDcDwCtrlEnable and dwTcHydDcDwFdNegEna. dwTcHydDcDwRefIndex Referencing cam. dwTcHydDcDwAcceptBlockedDrive Reserved. Not supported. dwTcHydDcDwBlockedDriveDetected Reserved. Not fully supported. Note: This signal suppresses any active velocity controller.