Knowledge Base PLC Library Hydraulics 238 Version: 1.4 Constant Hexadeci- mal Decimal Description dwTcHydAdsErrBusy 16#0708 1800 Already active. Possible causes: • the axis could not accept an instruction because it is already dealing with another task dwTcHydAdsErrNoFile 16#070C 1804 reserved: File is missing / not accessible. dwTcHydAdsErrSyntax 16#070D 1805 Syntax in command or file invalid. Possible causes: • invalid characters or character combinations were detected while reading a characteristic curve file stored in ASCII format • incomplete information was detected while reading a characteristic curve file stored in ASCII format dwTcHydAdsErrTimeout 16#0745 1861 Timeout.
Possible causes: • during a communication the response did not arrive within a designed time ◦ the chosen time is too short ◦ the connection is interrupted • the process has prevented processing of the command or delayed it beyond the designated time • the specified commands parameters have increased the time requirement beyond the designated value dwTcHydAdsErrNoAmsAddr 16#0749 1865 AMS/ADS address missing: • The ADS address of the device was not mapped to the corresponding variable of the input structure. dwTcHydErrCdNotCompatib le 16#4040 16448 The axis is incompatible with the required function. Possible causes:
• application software error dwTcHydErrCdIllegalOutput Number 16#4104 16644 The output number is outside the permitted range. Possible causes: • an MC ReadDigitalOutput BkPlcMc or _ _ MC WriteDigitalOutput BkPlcMc function block _ _ was called with an invalid parameter. dwTcHydErrCdNotSupport 16#4107 16647 Function or command not supported. Possible causes: • application software error dwTcHydErrCdCycleTime 16#4205 16901 Cycle time (fCycletime in ST TcHydAxParam) not _ permitted. Possible causes: • Parameterization error dwTcHydErrCdMissingEnc 16#4210 16912 There is no connection to an encoder interface (pStDeviceInput and/or pStDeviceOutput in Axis Ref BkPlcMc [} 67]). Possible causes:
_ _ • Application software error (the MC AxUtiStandardInit BkPlcMc function block _ _ was not called or not provided with the address of an ST TcPlcDeviceInput and an _ ST TcPlcDeviceOutput structure) _