TwinCAT PLC Library Hydraulics - Version 1.4 — 5.2 Global constants (from V3.0)

Knowledge Base PLC Library Hydraulics 239 Version: 1.4 Constant Hexadeci- mal Decimal Description dwTcHydErrCdMissingDrive 16#4212 16914 There is no connection to a drive interface (pStDeviceInput and/or pStDeviceOutput in Axis Ref BkPlcMc [} 67]). Possible causes: _ _ • Application software error (the MC AxUtiStandardInit BkPlcMc function block _ _ was not called or not provided with the address of an ST TcPlcDeviceInput and an _ ST TcPlcDeviceOutput structure) _ dwTcHydErrCdCannotSync hronize 16#421A 16922 Start distance inadequate when an MC GearInPos BkPlcMc() function block is called. _ _ Possible causes:

• the axis is too close to the sync point when the function block is activated • the dynamic axis parameters are inadequate dwTcHydErrCdIllegalGearF actor 16#421B 16923 The parameters of a gear coupling are not permitted. Possible causes: • the parameter of the function block is not permitted dwTcHydErrCdSoftEnd 16#4222 16930 The target position is located on the far side of an active software limit switch, and is therefore not permitted. dwTcHydErrCdLowDist 16#4228 16936 The travel distance is unacceptably small. dwTcHydErrCdIllegalStartTy pe 16#4239 16953 Invalid start type. dwTcHydErrCdCommandBu fferOverflow 16#423F 16959 Command buffer is full.

dwTcHydErrCdEncLostCam m 16#4253 16979 Reserved. Not supported. dwTcHydErrCdCtrlEnaLost 16#4260 16992 Controller enable was withdrawn during the motion. Possible causes: • the axis enable was withdrawn at an unexpected time due to a machine logic signal • application software error dwTcHydErrCdEncNoCam mFound 16#429C 17052 Reserved. Not supported. dwTcHydErrCdEncNoCam mEnd 16#429D 17053 Reserved. Not supported. dwTcHydErrCdEncNoSync Pulse 16#429E 17054 Reserved. Not supported. dwTcHydErrCdAcc 16#4309 17161 The acceleration is not acceptable. dwTcHydErrCdDec 16#430A 17162 The deceleration is not acceptable. dwTcHydErrCdJerk 16#430B 17163 The jerk limitation is invalid.

dwTcHydErrCdPtrPlcMc 16#4345 17221 No connection to one of the required axis interfaces (pStDeviceInput or pStDeviceOutput in Axis Ref BkPlcMc [} 67]). _ _ dwTcHydErrCdPtrMcPlc 16#4346 17222 No connection to one of the required axis interfaces (pStDeviceInput or pStDeviceOutput in Axis Ref BkPlcMc [} 67]). _ _ dwTcHydErrCdCtrlEna 16#4356 17238 Movement without controller enable is not permitted. dwTcHydErrCdNegFdEna 16#4357 17239 Movement in the direction of reducing positions without the negative direction advance enable is not permitted.