Editors 'Insert' 'Parallel Contact' Shortcut: + Use this command in the LD editor to insert a contact parallel to the marked position in the network. If the marked position is a coil (Cursor Position 3) or the connection between the contacts and the coils (Cursor Position 4), then the new contact will be connected in parallel to the entire previous contact connection. The contact is preset with the text "???". You can click on this text and change it to the desired variable or the desired constant. For this you can also use the Input Assistant. 'Insert' 'Function Block' Shortcut: + Use this command in order to insert an operator, a function block, a function or a program as a POU.
For this, the connection between the contacts and the coils (cursor position 4), or a coil (cursor position 3), must be marked. The new POU at first has the designation AND. If you wish, you can change this designation to another one. For this you can also use the Input Assistant. Both standard and selfdefined POUs are available. The first input to the POU is placed on the input connection, the first output on the output connection; thus these variables must definitely be of type BOOL. All other in- and outputs of the POU are filled with the text „???“. These prior entries can be changed into other constants, variables or addresses. For this you can also use the Input Assistant.
'Insert' 'Coil' Shortcut: + You can use this command in the LD editor to insert a coil in parallel to the previous coils. If the marked position is a connection between the contacts and the coils (Cursor Position 4), then the new coil will be inserted as the last. If the marked position is a coil (Cursor Position 3), then the new coil will be inserted directly above it. The coil is given the text "???" as a default setting. You can click on this text and change it to the desired variable. For this you can also use the Input Assistant. POUs with EN Inputs If you want to use your LD network as a PLC for calling up other POUs , then you must merge a POU with an EN input.
Such a POU is connected in parallel to the coils. Beyond such a POU you can develop the network further, as in the Function Block Diagram. You can find the commands for insertion at an EN POU under the menu item "Insert" "Insert at Blocks" . An operator, a function block, or a function with EN input performs the same way as the corresponding POU in the Function Block Diagram, except that its execution is controlled on the EN input. This input is annexed at the connecting line between coils and contacts. If this connection carries the information "On", then the POU will be evaluated. If a POU has been created once already with EN input, then this POU can be used to create a network.
This means that data from usual operators, functions, and function blocks can flow in an EN POU and an EN POU can carry data to such usual POUs. TX1200 139 Version: 1.3