Beckhoff Automation GmbH & Co. KG TX1200 — 4.3 Managing Projects

Individual Components dialog Communication parameters (see menu ‘Online‘ ‘Communication parameters‘) for setting the transmission parameters when no connection exists yet to the PLC. Once an on-line connection has been created, the system checks whether the same named project files already exist in the directory on your computer hard disc. When this is the case you receive the dialogue Load the project from the controller where you can decide whether the local files should be replaced by those being used by the controller. (This sequence is the reverse of the sequence of 'Online' 'Load source code', with which the project source file is stored in the controller.

Do not confuse with 'Create Boot project'!) Note that after uploading a project, it is still without a name. You must save it under a new name. If no project was loaded on the controller yet, you will receive a corresponding error message. Standard dialog for opening a file in TwinCAT PLC Control The option Open project from Source code manager is used to open a project that is managed in an ENI project database. The requirement is that you have access to an ENI server that serves the database. Click the ENI... button to get the 'Project Objects' dialog for establishing the connection to the server.

Enter the appropriate access data here (TCP/IP address, port, user name, password, read only access) and the directory of the database (project name) from which the objects are to be retrieved from the database and confirm with Next. Then the dialog closes and the corresponding one for the category ' Shared objects ' opens. Enter your access data here as well. Finish closes this dialog and automatically retrieves and opens the objects of the set directories. Now you can make the desired settings in the project options, which should apply to the further editing of the project.

If you want to continue managing the project in the database, parameterize accordingly in the dialogs of the Project database category. In the File menu, below the ' Exit ' menu item, the last opened projects are listed. When you select one of them, this project will be opened. If passwords or user groups have been defined for the project, a dialog for entering the password appears. 'File' 'Close' With this command you close the currently-open project. If the project has been changed, then TwinCAT PLC Control asks if these changes are to be saved or not. If the project to be saved carries the name "Untitled", then a name must be given to it (see "File" "Save as"). TX1200 67 Version: 1.3