omron — Ix14 Motor x Negative Software Position Limit

PMAC Product Guide At any given time, one coordinate system’s status bit can be output to several places; which system depends on what coordinate system is hardware-selected on the panel input port if I2=0, or what coordinate system is software-addressed from the host (&n) if I2=1. The outputs that work in this way are F1LD/ (pin 23 on connector J2), F1ER (line IR3 into the programmable interrupt controller (PIC) on PMAC-PC, line IR6 into the PIC on PMAC-STD) and, if E28 connects pins 1 and 2, FEFCO/ (on the JMACH connectors). Note: The units of Ix12 are 1/16 of a count. Therefore, this parameter must hold a value 16 times larger than the number of counts at which the limit will occur.

For example, if the limit is to be 1000 counts, Ix12 should be set to 16,000. Ix13 Motor x Positive Software Position Limit Range: ± 2 47 Default: 0 Units: Encoder Counts This parameter sets the position for motor x which if exceeded in the positive direction causes a deceleration to a stop (controlled by Ix15) and allows no further positive position increments or positive output commands as long as the limit is exceeded. If this value is set to zero, there is no positive software limit (to set 0 as a limit, use 1). This limit is de-activated automatically during homing search moves, until the home trigger is found. It is active during the post-trigger move.

Starting in firmware 1.15, bit 17 of Ix25 does not de-activate the software limits. Permanent de-activation is done by setting the value of the software limit to zero. This limit is referenced to the most recent power-up zero position or homing move zero position. The physical position at which this limit occurs is not affected by axis offset commands (e.g. PSET, X= ), although these commands will change the reported position value at which the limit occurs. Ix14 Motor x Negative Software Position Limit Range: ± 2 47 Default: 0 (Disabled) Units:

Encoder Counts This parameter sets the position for motor x which if exceeded in the negative direction causes a deceleration to a stop (controlled by Ix15) and allows no further negative position increments or negative output commands as long as the limit is exceeded. If this value is set to zero, there is no negative software limit (to set 0 as a limit, use -1). This limit is de-activated automatically during homing search moves, until the trigger is found. It is active during the post-trigger move. Starting in firmware 1.15, bit 17 of Ix25 does not de-activate the software limits. Permanent de-activation is done by setting the value of the software limit to zero.

This limit is referenced to the most recent power-up zero position or homing move zero position. The physical position at which this limit occurs is not affected by axis offset commands (e.g. PSET, X= ), although these commands will change the reported position value at which the limit occurs. I-Variables 109