omron — Ix17 Motor x Maximum Permitted Motor Program Acceleration

PMAC Product Guide Ix15 Motor x Deceleration Rate on Position Limit or Abort Range: Positive floating point Default: 0.25 Units: Counts/msec 2 This parameter sets the rate of deceleration that motor x will use if it exceeds a hardware or software limit, or has its motion aborted by command ( A or ) . Usually, this value should be set to a value near the maximum physical capability of the motor. It is not a good idea to set this value past the capability of the motor because doing so increases the likelihood of exceeding the following error limit, which stops the braking action and could allow the axis to coast into a hard stop. Note:

Do not set this parameter to zero or the motor will continue indefinitely after an abort or limit. Example: If the motor had 125 encoder lines (500 counts) per millimeter and it should decelerate at 4000 mm/sec 2 , set Ix15 to 4000 mm/sec 2 *500 cts/mm * sec 2 /1,000,000 msec 2 = 2 cts/msec 2 . Ix16 Motor x Maximum Permitted Motor Program Velocity Range: Positive floating point Default: 32.0 Units: Counts/msec This parameter sets a limit to the allowed velocity for LINEAR mode programmed moves for motor x, provided I13 equals zero (no move segmentation).

If a blended move command in a motion program requests a higher velocity of this motor, all motors in the coordinate system are slowed down proportionately so that motor x will not exceed this parameter, yet the path will not be changed. This limit does not affect transition-point, circular, or splined moves. The calculation does not take into account any feedrate override (% value other than 100). Note: If PMAC’s circular interpolation function is used at all, then I13 must be greater than zero and Ix16 will not be active as a velocity limit.

This parameter also sets the speed of a programmed RAPID mode move for the motor, provided that variable I50 is set to 1 (if I50 is set to 0, jog speed parameter Ix22 is used instead). This happens regardless of the setting of I13. Ix17 Motor x Maximum Permitted Motor Program Acceleration Range: P ositive floating point Default: 0.5 Units: counts/msec 2 This parameter sets a limit to the allowed acceleration in LINEAR -mode blended programmed moves for motor x, provided I13 equals zero (no move segmentation).

If a LINEAR move command in a motion program requests a higher acceleration of this motor given its TA and TS time settings, the acceleration for all motors in the coordinate system is stretched out proportionately so that motor x will not exceed this parameter, yet the path will not be changed. Because PMAC cannot look ahead through an entire move sequence, it sometimes cannot anticipate enough to keep acceleration within this limit. Refer to LINEAR-mode trajectories in the Writing a Motion Program in this manual. 110 I-Variables