PMAC Product Guide Fifth Character Returned: Bit 7 A-Axis used in Feedrate Calculations: See bit 23 description. Bit 6 A-Axis Incremental Mode: See bit 22 description. Bit 5 Radius Vector Incremental Mode: This bit is 1 if circle move radius vectors are specified incrementally (i.e. from the move start point to the arc center). It is 0 if circle move radius vectors are specified absolutely (i.e. from the XYZ origin to the arc center). See the INC ( R ) and ABS ( R ) commands. Bit 4 Continuous Motion Request: This bit is 1 if the coordinate system ahs requested of it a continuous set of moves (e.g. with an R command). It is 0 if this is not the case (e.g.
not running program, Ix92=1, or running under an S command). Sixth Character Returned: Bit 3 Move Specified by Time Mode: This bit is 1 if programmed moves in the coordinate system are currently specified by time (TM or TA), and the move speed is derived. It is 0 if programmed moves in the coordinate system are currently specified by feedrate (speed; F) and the move time is derived. Bit 2 Continuous Motion Mode: This bit is 1 if the coordinate system is in a sequence of moves that it is blending together without stops in between. It is 0 if it is not currently in such a sequence, for whatever reason. Bit 1 Single-Step Mode:
This bit is 1 if the motion program currently executing in this coordinate system has been told to Step one move or block of moves or if it has been given a Q ( Quit ) command. It is 0 if the motion program is executing a program by a R ( RUN ) command, or if it is not executing a motion program at all. Bit 0 Running Program: This bit is 1 if the coordinate system is currently executing a motion program. It is 0 if the coordinate system is not currently executing a motion program. Note that it becomes 0 as soon as it has calculated the last move and reached the final RETURN statement in the program, even if the motors are still executing the last move or two that have been calculated.
Compare to the motor Running Program status bit. Second Word Returned (Y:$0817, Y:$08D7, etc.) Seventh Character Returned: Bit 23 Program Hold Stop: This bit is 1 when a motion program running in the currently addressed coordinate system is stopped using the \ command from a segmented move ( LINEAR or CIRCLE mode with I13>0). Bit 22 Run-Time Error: This bit is 1 when the coordinate system has stopped a motion program due to an error encountered while executing the program (e.g. jump to non-existent label, insufficient calculation time, etc.) Bit 21 Circle Radius Error:
This bit is 1 when a motion program has been stopped because it was asked to an arc move whose distance was more than twice the radius (by an amount greater than Ix96). Bit 20 Amplifier Fault Error: This bit is 1 when any motor in the coordinate system has been killed due to receiving an amplifier fault signal. It is 0 at other times, changing from 1 to 0 when the offending motor is re-enabled. 148 Online Commands