omron — {axis}{data}^{data}[{axis}{data}^{data}...]

PMAC Product Guide In the case of PVT (position, velocity, time) motion mode, both the ending position and velocity are specified for each segment of each axis. The command consists of one or more groupings of axis labels with two data items separated by a colon character. The first data item for each axis is the scaled ending position or distance depending on whether the axis is in absolute ( ABS ) or incremental ( INC ) mode. Position scaling is determined by the axis definition statement and the second data item (after the colon) is the ending velocity.

The velocity units are the scaled position units as established by the axis definition statements divided by the time units as set by Ix90 for Coordinate System x. The velocity here is a signed quantity, not just a magnitude. See the examples in the PVT mode description of the Writing a Motion Program section of this manual. The time for the segment is the argument for the most recently executed PVT or TA command, rounded to the nearest millisecond. In PVT mode, if no velocity is given for the segment, PMAC assumes an ending velocity of zero for the segment. Examples: X1000:50 Y500:-32 Z737.2:68.93 A(P1+P2):(P3) B(SIN(Q1)):0 {axis}{data}^{data}[{axis}{data}^{data}...] Function :

Move until trigger Type : Motion program Syntax : {axis}{data}^{data}[{axis}{data}^{data}...] where {axis} is the character specifying which axis (X, Y, Z, A, B, C, U, V, W). the first {data} is a constant (no parentheses) or expression (in parentheses) representing the end position or distance in the absence of a trigger. the second {data} (after the ^ arrow) is a constant (no parentheses) or expression (in parentheses) representing the distance from the trigger position. [{axis}{data}^{data}...] is the optional specification of simultaneous movement for more axes. In the RAPID move mode, this move specification permits a move-until-trigger function.

The first part of the move description for an axis (before the ^ sign) specifies where to move in the absence of a trigger. It is a position if the axis is in absolute mode; it is a distance if the axis is in incremental mode. In both cases the units are the scaled axis user units. If no trigger is found before this destination is reached, the move is a standard RAPID move. The second part of the move description for an axis (after the ^ sign) specifies the distance from the trigger position to end the post-trigger move if a trigger is found. The distance is expressed in the scaled axis user units.

Each motor assigned to an axis specified in the command executes a separate move-until-trigger. All the assigned motors will start together, but each can have its own trigger condition. If a common trigger is required, the trigger signal must be wired into all motor interfaces. Each motor can finish at a separate time; the next line in the program will not start to execute until all motors have finished their moves. No blending into the next move is possible. 198 Buffer Commands