omron — Application Presets: A1-06

4.5 Application Presets Start-Up Programming & Operation Always disabled for single phase drives. 4 Note: A sequence to release the brake is needed when the multi-function output photocoupler P2-PC closes. Refer to Hoist Application Preset Specifics on page 115 for more information. Note: Perform Auto-Tuning after selecting the Hoist Application Preset. Table 4.16 Parameters Automatically Saved as Preferred (A2-01 to A2-16) Note: Read the instructions listed in Hoist Application Preset Specifics on page 115 when using Hoist Application Preset. A1-06 = 7: Travelling Application Table 4.17 Parameters and Settings OYMC TOEP C71060622-01-OY V1000 User Manual 113 No.

Parameter Name Optimum Setting H2-03 Terminals P2 Function Selection (open-collector) 5: Frequency Detection 2 (FOUT) L2-03 Momentary Power Loss Minimum Baseblock Time 0.3 s L3-04 Momentary Power Loss Voltage Recovery Ramp Time 0: Disabled L4-01 Speed Agreement Detection Level 2.0 Hz L4-02 Speed Agreement Detection Width 0.0 Hz L6-01 Torque Detection Selection 1 8: UL3 at RUN -Fault L6-02 Torque Detection Level 1 5% L6-03 Torque Detection Time 1 0.5 s L8-05 Input Phase Loss Protection Selection 1: Enabled L8-07 Output Phase Loss Protection 1: Enabled L8-38 Carrier Frequency Reduction 0: Derated when operating at 6 Hz or less L8-41 Current Alarm Selection 1: Enabled (alarm is output) No.

Parameter Name No. Parameter Name A1-02 Control Method Selection d1-02 Frequency Reference 2 b1-01 Frequency Reference Selection d1-03 Frequency Reference 3 b6-01 Dwell Reference at Start E1-08 Mid Output Frequency Voltage b6-02 Dwell Time at Start H2-01 Terminals MA, MB, and MC Function Selection C1-01 Acceleration Time 1 L1-01 Motor Overload Protection Selection C1-02 Deceleration Time 1 L4-01 Speed Agreement Detection Level C6-02 Carrier Frequency Selection L6-02 Torque Detection Level 1 d1-01 Frequency Reference 1 L6-03 Torque Detection Time 1 No. Parameter Name Optimum Setting A1-02 Control Mode 0: V/f Control b1-01 Frequency Reference Selection 0: Operator