4.5 Application Presets ■ Hoist Application Preset Specifics This section lists some important points when using the Hoist Application Preset (A1-06 = 6). Conditions for Opening and Closing the Holding Brake When an external baseblock command is present, the frequency reference will be kept when a run command is entered. To avoid improper brake release make sure that frequency detection is set so that it does not operate during baseblock (L4-07 = “0” , default). To activate and release the brake using the multi-function output terminals P1-PC, program the drive as shown in the table below: Use an output signal as described below to operate the holding brake in a hoist application.
Start-Up Programming & Operation 4 This setting range is available when using OLV Control. In V/f Control, set the level as the motor rated slip frequency pulse 0.5 Hz. Not enough motor torque will be created if this value is set too low, and the load may tend to slip. Make sure this value greater than the minimum output frequency and greater than the value of L4-02 as shown in the diagram below. If this value is set too high, there may be a jolt at start. Adjust Hysteresis for Frequency Detection 2 by changing the frequency detection width (L4-02) between 0.0 and 0.5 Hz. If the load slips during stop, make incremental changes of 0.1 Hz until the load no longer slips.
L4-02 L4-01 Output Frequency Time Frequency Detection 2 OFF ON Sequence Circuit Design for Opening and Closing the Holding Brake Design the braking sequence as follows: The brake should release when terminal P2-PC closes in response to the run conditions on the sequence side. When a fault signal is output, the brake should close. When an up or down command is entered, the brake should release. OYMC TOEP C71060622-01-OY V1000 User Manual 115 Brake Open/Close Brake Activation Level Control Mode Function Parameter Signal Parameter V/f OLV OLV for PM Frequency Detection 2 L4-07 = 0 H2-02 = 5 Frequency Detection Level Frequency Detection Width L4-01 = 1.0 to 3.0 Hz L4-02 = 0.0 to 0.5 Hz O O -