4.5 Application Presets Figure 4.10 Figure 4.10 Holding Brake Circuit Design Time chart for Opening and Closing the Holding Brake A sequence to open and close the holding brake appears in the diagram below. When changing the speed using an analog signal, make sure that the source of the frequency reference is assigned to the control circuit terminals (b1-01 = 1). Figure 4.11 Input S1-SC UP OFF ON S6-SC High/Low Speed OFF ON d1-01 (b1-01 must be 0) Time Output Output Frequency d1-03 L4-01 b4-01 ON P2-PC Frequency Detection 2 (H2-01 = 05) OFF DC Injection Braking Brake Closed Open Closed Figure 4.11 Holding Brake Time Chart ◆ User Parameters:
A2-01 to A2-32 The user can select 32 parameters and set them to parameters A2-01 through A2-32 to save time scrolling through the parameter menu. The list of User Parameters can also track the most recently edited settings and save those parameters to this list. Default setting value is dependent on parameter A1-06, Application Selection.
116 OYMC TOEP C71060622-01-OY V1000 User Manual Drive 24 V Fault Contact Holding brake MA auxilary relay coil UP S1 MB Safety UP 㧔Forward㧕 Circuit BR DOWN S2 MC DOWN 㧔Reverse㧕 BR High speed S6 Frequency Detect 2 㧔Multi-step speed 2) P2 ONBrake energized Low speed 㧔DC 30V 1 ATCVKPI㧕 SC PC Fault Contact MA S1 MB 㧔Forward㧕 MC S2 㧔Reverse㧕 S6 Frequency Detect 2 㧔Multi-step speed 2) P2 SC PC No. Parameter Name Setting range Default A2-01 to A2-32 User Parameters, 1 to 32 b1-01 to o2-08